Electric actuated ball valve with V port / multiple degree V-notch available
Features
V-port ball valve
- V-port on the ball, not in the seat, eliminates the need to replace seats.
- WCB, CF8(SS304), CF8M(SS316) available
- Size from DN15 to DN100, 1/2” to 4”
- Blowout proof stem design
- Thread type and flange type available
- High platform ISO5211 multi flange direct mounting
- Different V-port angles optional, 30°,60°,90°, specific type, etc.
Electric actuator
- Quarter turn with mechanical limits
- Integral design of motor/control box/housing to make whole actuator compact
- Over torque protection by torque test function of smart full potted controller
- High performance EMC with EFT, ESD and high voltage surge tested for control pack
- Heavy duty motor with thermal overload protection
- Hard high pressure die cast aluminum housing with weather proof IP67 and NEMA 4X
- Valve position indicator/flat indicator or convex indicator available
- Manual override with wrench or handwheel
- CSA Certification per UL and CSA standard/CE marked/RoHS 3.0 passed
Description
DCL V-port electric ball valves can achieve more precise consistent flow control than round ported ball valves. The flow curves of V-port valves are closer to linear. When they are driven by modulating type electric actuators with electric positioning system, the V-port valves can be used for accurate flow adjustment, to replace the linear stroke control valve. The whole stroke travel time is commonly shorter.
Specification
Actuator Type | Butterfly Valve(≤PN1.0MPa) | Ball Valve(≤PN1.6MPa) | Vent Valve(≤PN0.1MPa) |
DCL-02 | ≤DN40 | ≤DN32 | |
DCL-05 | DN50~65 | DN40 | DN50~80 |
DCL-10 | DN80~100 | DN50~65 | DN100~200 |
DCL-20 | DN125~150 | DN80~100 | DN250~300 |
DCL-40 | DN200 | DN125 | DN350~450 |
DCL-60 | DN250 | DN150 | DN500~600 |
DCL-100 | DN300 | DN200 | DN700~800 |
DCL-160 | DN350~400 | DN250 | DN900 |
DCL-250 | DN450~600 | DN300~350 | DN1000~1200 |